Definition(s)


ESD

Emergency Shutdown System.

Source: API STD 521, Pressure-relieving and Depressuring Systems, Sixth Edition, January 2014. Global Standards

ESD

Emergency shutdown.

Source:  DNVGL-RP-G108, Cyber security in the oil and gas industry based on IEC 62443, DNV GL, September 2017. Global Standards

Source: ISO 16530-1:2017, Petroleum and natural gas industries — Well integrity – Part 1: Life cycle governance, First Edition, March 2017. Global Standards

Source: ISO 17776:2016, Petroleum and natural gas industries — Offshore production installations — Major accident hazard management during the design of new installations, Second Edition, December 2016. Global Standards

Source:API SPECIFICATION 19TT, Specification for Downhole Well Test Tools and Related Equipment, First Edition, October 2016. Global Standards

ESD

Shut down of the facility under emergency conditions during which the internal pressure in a production riser can increase above the normal operating pressure.

Source: API Standard 2RD, Dynamic Risers for Floating Production Systems, Second Edition, September 2013. Global Standards

ESD

Emergency shut-down.

Source: API Standard 2RD, Dynamic Risers for Floating Production Systems, Second Edition, September 2013. Global Standards

Source: API RP 14G, Recommended Practice for Fire Prevention and Control on Fixed Open-type Offshore Production Platforms: Upstream Segment, Fourth Edition, April 2007. Global Standards

Source: API RP 17A, Design and Operation of Subsea Production Systems—General Requirements and Recommendations, Fourth Edition, Reaffirmed 2011. Global Standards

Source: API SPEC 17F, Specification for Subsea Production Control Systems, Second Edition, December 2006 (Reaffirmed April 2011). Global Standards

Source: 117 OLF, Norwegian Oil and Gas Association recommended guidelines for Well Integrity, No. 117, Revision No. 4, June 2011. Global Standards

Source: International Association of Drilling Contractors, Appendix 2 to Health, Safety and Environment Case Guidelines for Offshore Drilling Contractors, Issue 3.3.2, February 2010. IADC Guidelines

Source: ISO 13702:2015, Petroleum and natural gas industries — Control and mitigation of fires and explosions on offshore production installations — Requirements and guidelines, Second Edition, August 2015. Global Standards

Source: ISO 15544:2000, Petroleum and natural gas industries – Offshore production installations – Requirements and guidelines for emergency. Global Standards

Source: ISO 17776:2000, Petroleum and natural gas industries – Offshore production installations – Guidelines on tools and techniques for hazard identification and risk assessment. Global Standards

Source: ISO 20815:2008, Petroleum, petrochemical and natural gas industries – Production assurance and reliability management. Global Standards

Source: NOPSEMA Guidance Note: Control Measures and Performance Standards, N-04300 GN0271, Australia, Revision 3, December 2011. Regulatory Guidance

Source: NORSOK D-010, Well integrity in drilling and well operations, Rev. 3, August 2004. Global Standards

Source: NORSOK D-002, Well intervention equipment, Rev. 2, June 2013. Global Standards

Source: Rules for Classification – Offshore units, DNVGL-OU-0101, Offshore drilling and support units, DNV GL, July 2015. Global Standards

 

ESD

Control actions undertaken to shut down equipment or processes in response to a hazardous situation.

Source: ISO 13702:2015, Petroleum and natural gas industries — Control and mitigation of fires and explosions on offshore production installations — Requirements and guidelines, Second Edition, August 2015. Global Standards

 

ESD

Emergency shutdown system.

Source: Prevention of Fire and Explosion, and Emergency Response on Offshore Installations, Offshore Installations (Prevention of Fire and Explosion, and Emergency Response) Regulations 1995, Approved Code of Practice and guidance (UK HSE L65), Second Edition, 1997. Regulatory Guidance

Source: NORSOK D-001, Drilling facilities, Rev. 3, December 2012. Global Standards