Definition(s)


Zone

A method of specifying the probability that a location is made hazardous by the presence, or potential presence, of flammable concentrations of gases and vapors, or combustible mixtures of dusts.

Source: API Recommended Practice 14FZ, Recommended Practice for Design, Installation, and Maintenance of Electrical Systems for Fixed and Floating Offshore Petroleum Facilities for Unclassified and Class I, Zone 0, Zone 1, and Zone 2 Locations, Second Edition, May 2013. Global Standards

Source: API RP 14F, Design, Installation, and Maintenance of Electrical Systems for Fixed and Floating Offshore Petroleum Facilities for Unclassified and Class 1, Division 1 and Division 2 Locations, Fifth Edition, July 2008. Global Standards

 

Zone 0 (IEC)

An area in which an explosive gas atmosphere is present continuously or for long periods. (See IEC 60050, IEV 426-03-03.)

Source: API Recommended Practice 14FZ, Recommended Practice for Design, Installation, and Maintenance of Electrical Systems for Fixed and Floating Offshore Petroleum Facilities for Unclassified and Class I, Zone 0, Zone 1, and Zone 2 Locations, Second Edition, May 2013. Global Standards

Source: API RP 14F, Design, Installation, and Maintenance of Electrical Systems for Fixed and Floating Offshore Petroleum Facilities for Unclassified and Class 1, Division 1 and Division 2 Locations, Fifth Edition, July 2008. Global Standards

 

Zone 0, Class I (NEC)

A Class I, Zone 0 location is a location 1) in which ignitable concentrations of flammable gases or vapors are present continuously; or 2) in which ignitable concentrations of flammable gases or vapors are present for long periods of time, see NEC Section 505.5(B)(1).

Source: API Recommended Practice 14FZ, Recommended Practice for Design, Installation, and Maintenance of Electrical Systems for Fixed and Floating Offshore Petroleum Facilities for Unclassified and Class I, Zone 0, Zone 1, and Zone 2 Locations, Second Edition, May 2013. Global Standards

 

Zone 0, Class I (NEC)

A Class I, Zone 0 location is a location 1) in which ignitable concentrations of flammable gases or vapors are present continuously; or 2) in which ignitable concentrations of flammable gases or vapors are present for long periods of time, see NEC Section 505-9(a).

Source: API RP 14F, Design, Installation, and Maintenance of Electrical Systems for Fixed and Floating Offshore Petroleum Facilities for Unclassified and Class 1, Division 1 and Division 2 Locations, Fifth Edition, July 2008. Global Standards

 

Zone 0

Place in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is present continuously or for long periods or frequently.[IEV 426-03-03, modified]
NOTE The MODU code definition is “Zone 0: in which an explosive gas/air mixture is continuously present or present for long periods.”

Source: IEC 61892-7, Mobile and fixed offshore units – Electrical installations – Part 7: Hazardous areas. Global Standards

 

Zone 1 (IEC)

An area in which an explosive gas atmosphere is likely to occur in normal operation, see IEC 60050, IEV 426-03-04.

Source: API Recommended Practice 14FZ, Recommended Practice for Design, Installation, and Maintenance of Electrical Systems for Fixed and Floating Offshore Petroleum Facilities for Unclassified and Class I, Zone 0, Zone 1, and Zone 2 Locations, Second Edition, May 2013. Global Standards

Source: API RP 14F, Design, Installation, and Maintenance of Electrical Systems for Fixed and Floating Offshore Petroleum Facilities for Unclassified and Class 1, Division 1 and Division 2 Locations, Fifth Edition, July 2008. Global Standards

 

Zone 1, Class I (NEC)

A Class I, Zone 1 location is a location 1) in which ignitable concentrations of flammable gases or vapors are likely to exist under normal operating conditions; or 2) in which ignitable concentrations of flammable gases or vapors may exist frequently because of repair or maintenance operations or because of leakage; or 3) in which equipment is operated or processes are carried on, of such a nature that equipment breakdown or faulty operations could result in the release of ignitable concentrations of flammable gases or vapors and also cause simultaneous failure of electrical equipment in a mode to cause the electrical equipment to become a source of ignition; or 4) that is adjacent to a Class I, Zone 0 location from which ignitable concentrations of vapors could be communicated, unless communication is prevented by adequate positive-pressure ventilation from a source of clean air and effective safeguards against ventilation failure are provided, see NEC Article 505.5(B)(2).

Source: API Recommended Practice 14FZ, Recommended Practice for Design, Installation, and Maintenance of Electrical Systems for Fixed and Floating Offshore Petroleum Facilities for Unclassified and Class I, Zone 0, Zone 1, and Zone 2 Locations, Second Edition, May 2013. Global Standards

 

Zone 1, Class I (NEC)

A Class I, Zone 1 location is a location 1) in which ignitable concentrations of flammable gases or vapors are likely to exist under normal operating conditions; or 2) in which ignitable concentrations of flammable gases or vapors may exist frequently because of repair or maintenance operations or because of leakage; or 3) in which equipment is operated or processes are carried on, of such a nature that equipment breakdown or faulty operations could result in the release of ignitable concentrations of flammable gases or vapors and also cause simultaneous failure of electrical equipment in a mode to cause the electrical equipment to become a source of ignition; or 4) that is adjacent to a Class I, Zone 0 location from which ignitable concentrations of vapors could be communicated, unless communication is prevented by adequate positive-pressure ventilation from a source of clean air and effective safeguards against ventilation failure are provided, see NEC Article 505-9(b).

Source: API RP 14F, Design, Installation, and Maintenance of Electrical Systems for Fixed and Floating Offshore Petroleum Facilities for Unclassified and Class 1, Division 1 and Division 2 Locations, Fifth Edition, July 2008. Global Standards

 

Zone 1

Place in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is likely to occur in normal operation occasionally. [IEV 426-03-04, modified]
NOTE The MODU code definition is “Zone 1: in which an explosive gas/air mixture is likely to occur in normal operation.”

Source: IEC 61892-7, Mobile and fixed offshore units – Electrical installations – Part 7: Hazardous areas. Global Standards

 

Zone 2 (IEC)

An area in which an explosive gas atmosphere is not likely to occur in normal operation and, if it does occur, is likely to do so only infrequently and will exist for a short period only, see IEC 60050, IEV 426-03-05.

Source: API Recommended Practice 14FZ, Recommended Practice for Design, Installation, and Maintenance of Electrical Systems for Fixed and Floating Offshore Petroleum Facilities for Unclassified and Class I, Zone 0, Zone 1, and Zone 2 Locations, Second Edition, May 2013. Global Standards

Source: API RP 14F, Design, Installation, and Maintenance of Electrical Systems for Fixed and Floating Offshore Petroleum Facilities for Unclassified and Class 1, Division 1 and Division 2 Locations, Fifth Edition, July 2008. Global Standards

 

Zone 2, Class I (NEC)

A Class I, Zone 2 location is a location 1) in which ignitable concentrations of flammable gases or vapors are not likely to occur in normal operation, and if they do occur, will exist only for a short period; or 2) in which volatile flammable liquids, flammable gases, or flammable vapors are handled, processed, or used, but in which the liquids, gases, or vapors normally are confined within closed containers or closed systems from which they can escape only as a result of accidental rupture or breakdown of the containers or system, or as the result of the abnormal operation of the equipment with which the liquids or gases are handled, processed, or used; or 3) in which ignitable concentrations of flammable gases or vapors normally are prevented by positive mechanical ventilation, but which may become hazardous as the result of failure or abnormal operation of the ventilation equipment; or 4) that is adjacent to a Class I, Zone 1 location, from which ignitable concentrations of flammable gases or vapors could be communicated, unless such communication is prevented by adequate positive-pressure ventilation from a source of clean air, and effective safeguards against ventilation failure are provided, see NEC Section 505.5(B)(3).

Source: API Recommended Practice 14FZ, Recommended Practice for Design, Installation, and Maintenance of Electrical Systems for Fixed and Floating Offshore Petroleum Facilities for Unclassified and Class I, Zone 0, Zone 1, and Zone 2 Locations, Second Edition, May 2013. Global Standards

 

Zone 2, Class I (NEC)

A Class I, Zone 2 location is a location 1) in which ignitable concentrations of flammable gases or vapors are not likely to occur in normal operation, and if they do occur, will exist only for a short period; or 2) in which volatile flammable liquids, flammable gases, or flammable vapors are handled, processed, or used, but in which the liquids, gases, or vapors normally are confined within closed containers or closed systems from which they can escape only as a result of accidental rupture or breakdown of the containers or system, or as the result of the abnormal operation of the equipment with which the liquids or gases are handled, processed, or used; or 3) in which ignitable concentrations of flammable gases or vapors normally are prevented by positive mechanical ventilation, but which may become hazardous as the result of failure or abnormal operation of the ventilation equipment; or 4) that is adjacent to a Class I, Zone 1 location, from which ignitable concentrations of flammable gases or vapors could be communicated, unless such communication is prevented by adequate positive-pressure ventilation from a source of clean air, and effective safeguards against ventilation failure are provided, see NEC Section 505-9(c).

Source: API RP 14F, Design, Installation, and Maintenance of Electrical Systems for Fixed and Floating Offshore Petroleum Facilities for Unclassified and Class 1, Division 1 and Division 2 Locations, Fifth Edition, July 2008. Global Standards

 

Zone 2

Place in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only.[IEV 426-03-05, modified]
NOTE 1 In this definition, the word “persist” means the total time for which the flammable atmosphere will exist. This will normally comprise the total of the duration of the release, plus the time taken for the flammable atmosphere to disperse after the release has stopped.
NOTE 2 Indications of the frequency of the occurrence and duration may be taken from codes relating to specific industries or applications.
NOTE 3 The MODU code definition is “Zone 2: in which an explosive gas/air mixture is not likely to occur, or in which such a mixture, if it does occur, will only exist for a short time.”3

 

Zone

“Zone” means any stratum or strata designated by the Minister as a zone, either generally or in respect of any designated area, or any specified well or wells (zone).

Source: Canada Oil and Gas Drilling and Production Regulations, C.R.C., c. 1517, February 2013. Regulations

 

Zone

“Zone” means any stratum or any sequence of strata and includes, for the purposes of the definition “commingled production”, section 7, subsection 61(2), sections 64 to 66 and 73, subsection 82(2) and section 85, a zone that has been designated as such by the Board under section 4 (couche).

Source: Canada Oil and Gas Drilling and Production Regulations, SOR/2009-315, February 2013. Regulations

Source: Drilling and Production Guidelines, The Canada-Nova Scotia Offshore Petroleum Board and Canada-Newfoundland and Labrador Offshore Petroleum Board, Canada, March 31, 2011. Regulatory Guidance

 

Zone

Part of a hazardous area based upon the frequency of the occurrence and duration of an explosive gas atmosphere.

Source: ISO 13702:2015, Petroleum and natural gas industries — Control and mitigation of fires and explosions on offshore production installations — Requirements and guidelines, Second Edition, August 2015. Global Standards

 

Zone

“Zone” means any stratum or any sequence of strata and includes, for the purposes of the definition “commingled production”, section 7, subsection 61(2), sections 64 to 66 and 74, subsection 83(2) and section 86, a zone that has been designated as such by the Board under section 4; couche.

Source: Nova Scotia Offshore Petroleum Drilling and Production Regulations, SOR/2009-317, Canada, current to May 31, 2012. Regulations

 

Zone

See “security zone

Source: ANSI/ISA–99.00.01–2007, Security for Industrial Automation and Control Systems, Part 1: Terminology, Concepts, and Models, 29 October 2007. National Standard

Comments are closed.